Skip to main content
SANJHIHAWA|Clean Air System
सांझी हवा / SANJHIHAWAField Unit
PRACTICAL INDOOR DEFENSE • NO-NONSENSE SCIENCE

Home Air Lab

Clean air is achieved through mechanical filtration and physical envelope management, not folklore. Calculate exact CADR purifier sizing, explore room-by-room interventions, inspect the DIY Corsi-Rosenthal Box, and debunk pervasive smog myths.

DETERMINISTIC PURIFIER FORMULA

CADR Sizing Calculator

Units:
Formula: CADR = (Room Volume × ACH) ÷ Mixing Efficiency (0.85). Calculates the volume of filtered particle-free air delivered per hour.
REQUIRED SPECIFICATION
200m³/h Smoke CADR(118 CFM)

For your 34 m³ (1,200 cu ft) room, this purifier size will completely exchange all air every 12 minutes, providing approximately 80-85% reduction in indoor PM2.5 in a sealed room.

Commercial Match:
Standard Bedroom Purifier (₹8,000 - ₹11,000)
Crucial Buying Rule:
Require True HEPA H13. Strictly decline models advertising ionizers, UV-C with ozone, or plasma cleaners.
PHYSICAL ENVELOPE MANAGEMENT

Room-by-Room Smog Defenses

1. Purifier Placement

Place the purifier at least 1 foot away from walls. Direct the clean air outflow toward breathing height near the head of the bed, not facing a wardrobe or curtain.

2. Wet Mop Daily

Never use dry brooms or vacuum cleaners without HEPA exhaust bags. Wet mopping with a damp microfiber cloth captures settled particulate matter without resuspending it into your breathing zone.

3. Window Airing Window

Keep windows completely latched during morning and evening thermal inversion (6 AM - 11 AM). If ventilation is needed to clear CO2, crack windows for only 15 minutes between 1:00 PM and 3:00 PM.

OPEN-SOURCE CLEAN AIR HARDWARE

Build a DIY Corsi-Rosenthal Box (~₹3,500)

Invented by environmental engineer Dr. Richard Corsi and Jim Rosenthal. Delivers clean air delivery rates (CADR > 400 m³/h) matching ₹20,000 commercial purifiers at a fraction of the cost, with 5x longer filter life.

BILL OF MATERIALS (INDIAN NCR SOURCING)
  • 1× 20-Inch Box Fan (or Square Exhaust Fan)3-speed forward-curve axial fan (~50W power draw)
    ~₹1,800
  • 4× MERV 13 Furnace Filters (20" × 20" × 1")Filters 85% of PM2.5 with ultra-low static pressure drop
    ~₹1,400
  • 1× Heavy-Duty Duct Tape Roll & Cardboard SheetFor airtight edge sealing and the crucial circular fan shroud
    ~₹250
CRITICAL SHROUD PRINCIPLE: Box fans have square frames with circular spinning blades. Without a circular cardboard shroud taped to the fan face covering the four corners, turbulent air recirculates backward at blade tips. Adding a 14-inch circular cardboard aperture increases net airflow by up to 40%!
5-STEP ASSEMBLY INSTRUCTIONS
  1. 01.
    Cut Cardboard Base: Cut a 20" × 20" square piece of corrugated cardboard to serve as the sturdy bottom floor of your cube.
  2. 02.
    Assemble Filter Walls: Arrange the four MERV 13 filters as vertical walls. Ensure the airflow arrows on all four filter frames point inward toward the center of the box.
  3. 03.
    Tape All Seams Airtight: Use duct tape along every vertical corner and bottom edge. Ensure zero air bypass; incoming air must pass through filter media.
  4. 04.
    Mount Box Fan on Top: Place the 20-inch box fan atop the 4-filter cube with air blowing upward and outward into the room. Tape all four top edges securely.
  5. 05.
    Attach Cardboard Shroud: Cut a 14-inch circular hole in a 20" × 20" cardboard sheet and tape it to the front face of the fan to block corner vortex backdraft. Plug in and run on Speed 1 or 2.
EVIDENCE-BASED CORRECTIONS

Smog Myth-Buster

Click any common winter smog belief to inspect its physical mechanism and peer-reviewed consensus.

The popular NASA 1989 Clean Air Study measured volatile organic chemical (VOC) absorption in airtight, sealed 1m³ glass chambers over 24 hours. Subsequent peer-reviewed research (Cummings & Waring, 2020) confirmed that potted plants have near-zero Clean Air Delivery Rate (CADR) for fine particulate matter (PM2.5). Achieving the air exchange rate of typical indoor ventilation for VOCs would require 10 to 1,000 plants per square meter, while particle filtration remains negligible. Plants are pleasant decor, not smog defense.

Source & Scientific Citation: Journal of Exposure Science & Environmental Epidemiology (2020)