Skip to main content
SANJHIHAWA|Clean Air System
सांझी हवा / SANJHIHAWAField Unit
Scientific & Architectural Openness

How SanjhiHawa Works

Complete disclosure of physical mass-balance formulas, epidemiological constants, data sources, heuristic boundaries, and privacy guarantees.

Cardinal Rule #1

how_it_works.rule1_title

how_it_works.rule1_desc

Mathematical & Physical Formulations

01 / Indoor Single-Compartment Steady-State Mass Balance
C_in = C_out × [ (a × P) / (a + k) ]

C_in: Indoor PM2.5 concentration (µg/m³).

C_out: Outdoor ambient PM2.5 concentration (µg/m³).

a: Air exchange rate per hour (0.4/h for weatherstripped rooms, 0.8/h for standard apartments, 4.0/h for open windows).

P: Envelope penetration factor (0.55 to 0.98 dimensionless).

k: Total removal rate = k_natural (0.25/h surface deposition) + (CADR × η_mixing / V_room).

Source: Chen & Zhao (2011), Atmospheric Environment; Nazaroff (2004), Indoor Air.

02 / Inhaled PM2.5 Particulate Dose
Dose (µg) = C_effective × Inhalation_Rate(age, activity) × Duration (hours)
where C_effective = C_ambient × (1 - η_mask)

Inhalation Rates: Adults inhale ~0.30 m³/h at sleep, ~0.45 m³/h sedentary, up to 1.25 m³/h in moderate outdoor transit.

Fit-Adjusted Mask Efficiency (η_mask): Certified ISI N95 is set conservatively to 85% (accounting for realistic perimeter inward leakage vs 95% lab filter ratings); cloth mask is 20%; no mask is 0%.

Source: US EPA Exposure Factors Handbook (2011 Edition, Chapter 6) & ICMR Norms.

03 / Central Pollution Control Board (CPCB) NAQI Calculation
I = [ (I_hi - I_lo) / (C_hi - C_lo) ] × (C - C_lo) + I_lo
Linear sub-index interpolation applied strictly against official CPCB 24-hour breakpoints (0-30 Good, 31-60 Satisfactory, 61-90 Moderate, 91-120 Poor, 121-250 Very Poor, 250+ Severe).
04 / Berkeley Earth Cigarette-Equivalent Rule of Thumb
Cigarettes / day = 24h Average PM2.5 (µg/m³) ÷ 22 µg/m³

Developed by Muller & Muller (Berkeley Earth, 2015), equating the estimated lifetime mortality risk of breathing 22 µg/m³ of PM2.5 for 24 hours to smoking one cigarette per day.

Notice: This is an illustrative communication heuristic based on peer-reviewed environmental health literature.

Privacy by Design & Zero Server Persistence

SanjhiHawa does not require user accounts, passwords, email addresses, or phone numbers.

  • Your household members, family ages, and breathing vulnerability flags are stored exclusively in your browser's localStorage.
  • Profile data is transmitted as transient payload in POST requests to calculate your personalized day plan.
  • The API server does not write personal profiles to SQLite, logs, or external cloud storage.
  • You can wipe all stored data at any time via the "Delete My Data" button in Onboarding.

Real Atmospheric Telemetry & Scientific Standards

Standard / DomainGoverning Body / SourceImplementation in SanjhiHawa
CPCB National Air Quality Index (NAQI)Central Pollution Control Board, MoEFCC (Govt of India)Official 6-band linear piecewise sub-index interpolation for PM2.5 & PM10.
Atmospheric Model TelemetryCopernicus Atmosphere Monitoring Service (CAMS) / Open-MeteoHourly aerosol optical depth & ground-level PM2.5/PM10 forecast grids across India.
Graded Response Action Plan (GRAP)Commission for Air Quality Management (CAQM) in NCRStatutory Stage I (201-300), Stage II (301-400), Stage III (401-450), Stage IV (>450) mandates.
Physiological Inhalation DosimetryUS EPA Exposure Factors Handbook (Chapter 6) & ICMR NormsAge-stratified minute volume calculations across sedentary, transit, and sleep activities.
Indoor Aerosol Mass BalanceChen & Zhao (2011), Nazaroff (2004), Indoor AirPhysical infiltration, envelope penetration, and Clean Air Delivery Rate (CADR) decay.
Respiratory Particulate FiltrationBureau of Indian Standards (IS 9473) / NIOSHFit-adjusted penetration modeling for certified ISI N95 vs unsealed cloth masks.